Volume 6, Issue 3 (12-2016)                   cmja 2016, 6(3): 1634-1646 | Back to browse issues page


XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

moazzen ahmadi M, Mohammadpour A, Sajjadi M, Khorsand vakil zadeh A. Comparison of Transcutaneous electrical nerve stimulation in acupuncture points with Transcutaneous electrical nerve stimulation in incision site on physiologic parameters after appendectomy. cmja. 2016; 6 (3) :1634-1646
URL: http://cmja.arakmu.ac.ir/article-1-395-en.html

MSc student of Medical Surgical Nursing Gonabad University of Medical Sciences , Moazzenm2@mums.ac.ir
Abstract:   (1422 Views)

Introduction: Postoperative hemodynamic monitoring by nurses provides accessible information about the patient's cardiovascular function. Patients often experience the vital signs increase due to the activation of sympathetic system. The aim of this study is to compare the effect of Transcutaneous Electrical Nerve stimulation (TENS) in acupuncture points with the incision site on physiologic parameters after appendectomy.

Methods: This is one-blinded randomized control trial study. 140 patients after appendectomy were selected and randomly were divided into four groups (2 groups for testing, placebo and control group). In two TENS groups in incision site and acupuncture points, electrical stimulation has done for 20 minutes with 100 Hz frequency and physiologic parameters were evaluated before and after the intervention. ANOVA and repeated measurements were used to analyze data.

Result: A significant difference was observed between the four groups in terms of systolic pressure (P=0.001), diastolic pressure (P=0.008), pulse pressure (P=0.03) and respiratory rate (P=0.004). The pulse rate, respiration rate, systolic and diastolic blood pressure before and after the intervention in two intervention groups had a significant reduction (P<0.001). Physiological reduction in the electrical stimulation group at the incision site was higher compared to electrical stimulation on acupuncture points, but this reduction was not statistically significant (P>0.05(.

Conclusion: Transcutaneous electric nerve stimulation in the incision site had the highest reduction in physiologic parameters that can be offered as a part of nursing care for patients.

Full-Text [PDF 489 kb]   (511 Downloads)    
Type of Study: Research | Subject: Nursing and Midwifery

Add your comments about this article : Your username or Email:
Write the security code in the box

Send email to the article author


© 2015 All Rights Reserved | Complementary Medicine Journal of faculty of Nursing & Midwifery

Designed & Developed by : Yektaweb